Toshiba Air Conditioners - 7SKHP-E, Wall split, Heat Pump, R22

Split System Heat Pump, R22
Indoor Unit RAS-077SKHP-E RAS-107SKHP-E RAS-137SKHP-E
Outdoor Unit RAS-077S2AH-E RAS-107S2AH-E RAS-137S2AH-E
Power Supply (V/ph/Hz) 220-240/1/50 220-240/1/50 220-240/1/50
Cooling capacity, kW 2.00-2.00 2.50-2.55 3.56-3.60
EER (energy efficiency) 3.23-2.94 3.21-3.11 3.10-2.98
Energy consumption (cooling), kW 0.62-0.680.75-0.771.15-1.21
Operating current (cooling), A 2.87-2.923.66-3.625.15-5.00
Heating capacity, kW 2.00-2.05 2.70-2.72 3.95-4.00
COP (energy efficiency) 3.64-3.42 3.60-3.53 3.62-3.48
Energy consumption (heating), kW 0.55-0.60 0.75-0.77 1.09-1.15
Operating current (heating), A 2.55-2.603.5-3.45.04-4.97
Indoor Unit Dimensions (HxLxD), mm 250740195 250740195 275x790x205
Weight, kg 8 8 9
Air flow (cooling/heating), m³/h 490 / 490 540 / 560 570 / 600
Sound pressure level (H-M-L)(H/M+/M/L+/L)(dB) 39/34/29 40/36/32 41/35/31
Outdoor Unit Dimensions (HxLxD), mm 530660240 550780270 550780270
Weight, kg 29 32 39
Sound pressure level (cooling/heating), dB(A)
46/48 47/50 50/52
Flare connectionsLiquid, mm (inch) 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”)
Gas, mm (inch) 9.52 (3/8”) 9.52 (3/8”) 12.70 (1/2”)
Connection type Flare Flare Flare
Condensate drain, mm
16.30 16.30 16.30
Maximum pipe length, m 10 10 15
Pre-charged pipe length, m 10 10 15
Maximum height difference, m 5 5 6
Operating range (cooling/heating), º 15 to 43 / -10 to 24 15 to 43 / -10 to 24 15 to 43 / -10 to 24


Back to the section